  1. Navigate to HOME > TC > Options > Run Mode and ensure that the value is set to Free Run.

    In this mode, the timecode continues to count up, even when not recording on the camera, which is the behavior required by Shogun Live.

  2. Navigate to HOME > TC > Options > Mode and ensure that the value is set to Regen.

    In this mode, the timecode does not sync to the input once, but keeps in track with it, except when the camera is recording. If the timecode generator is also providing sync/genlock and the standards are set correctly on both outputs, there should be no discontinuities in the timecode received.

  3. As an additional check that the settings are correct, navigate to HOME > TC > Options > Regen Source and ensure that LTC in is displayed.

    The camera displays TC in white when it has a timecode. The timecode itself is also shown on the camera's display.

When the timecode is set up correctly, it is displayed in Shogun Live below the Vicon system timecode. In this example, it is listed as DeckLink C1, referencing the SDI capture card in use.

...