Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Ensure that in the Workspace, the Graph Plots view is selected.

    Tip

    (tick) Important
    If your Graph plots view displays No channel data available or a similar message, make sure you either have a live system connected or are reviewing a capture (see Prepare your Vicon system).

    Scroll pagebreak

  2. At the top left of the Graph Plots view, click the channel types menu and select the required channel type.

    Scroll pagebreak

    You can choose to display an independent channel (listed in bold text) or a dependent channel. If you want to display a dependent channel, you must select a channel source which can be:

    • A subject in the theTracking panel
    • A marker, prop or segment in the 3D View. A segment can be a labeling segment (prop or subject labeling skeleton), solving segment (subject solving skeleton) or retarget segment (subject retargeting skeleton).
    • A camera in the System panel or Cameras view
    Tip

    (tick) Tip
    If you select a dependent channel type and have not yet selected the required channel source(s), the Graph Plots view displays a message telling you the channel source(s) that you must select to display the selected channel type.

  3. Change the data displayed in the active channel using additional controls in the Graph Plots toolbar. For more information, see:  

To add a graph trace to a subplot in subplot in Graph Plots:

If you already have at least one channel active in a Graph Plots view and want to add a trace to a subplot:

...

Info
Note
In general, any new channel source or type that you select is displayed according to the current settings in the Graph Plots toolbar. The duration of data displayed in the trace depends on whether you are reviewing live or captured data.
  • If your system is live, the duration of the trace is limited initially by the Live data range (see Change the scale of graphed data) or the Pause Buffer Size (see seeVicon Shogun fundamentals), whichever is shorter (in seconds).
  • If your system is in review mode, it displays the trace for the entire capture duration.

...

As you customize your graph plots, see Graph Plots mouse actions to understand how to control the behavior of the graph plots window.  

Manage graph plots

After you have added all the desired channels and customized the layout of the Graph Plot window, you can also:

  • Lock the current selection of channels using the Lock channel selection button Image Modified . When selected, clicking on potential channel sources does not add or remove channels. See Lock channel selection.

  • Save the current Graph Plot layout (including pinned channels) or load a previous Graph Plot layout using usingGraph Settings. See Save and load Graph Plots layouts.

Anchor
LockChannelSelection
LockChannelSelection
Lock channel selection

Scroll tablelayout
orientationdefault
sortDirectionASC
repeatTableHeadersdefaultstyle
widths12%, 88%
style
sortByColumn1
tableStylingconfluence
sortEnabledfalse
cellHighlightingtrue

...

Graph Settings only apply to the Graph Plots window and are a subset of the overall View Settings (see Live - Customize views).   This means:

  • You can load different Graph Plot layouts while maintaining the current Shogun layout.
  • Loading a View setting will load the graph settings that were specified as a part of that View configuration.
  • Graph Settings do not have a specific auto-save feature but are included as part of the View Settings auto-save.

To change the interval at which files are auto-saved, go to Preferences (Shift+P), select User Preferences > General , and change the value in the Auto-save interval field from the default (60 seconds).

Scroll pagebreak
To save new graph settings:

  1. On the Graph Plots toolbar, click Graph Settings Image Modified.

  2. Click Manage.
  3. In the Manage Graph Settings dialog box, click the Save button.
  4. Enter a name for the graph settings to save.
  5. Click OK.

...

Alternatively, import the required settings. To import settings:

  1. On the Graph Plots toolbar, click Graph Settings Image Modified.

  2. Click Manage.
  3. In the Manage Graph Settings dialog box, click the Import button.
  4. Select the settings to import.

    Tip

    (tick) Tip
    Settings have the extension .Graph.