Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

This command compares the data on each side of a gap to other markers to determine if they move rigidly with the selected marker around the gap.  

The fragment considered on each side of the gap must be at least 1 and is clamped at no more than 360 keys. Gaps within the range of 10 or less are considered part of the fragment.

...

Scroll tablelayout
style
sortDirectionASC
repeatTableHeadersdefault
widths24%, 12%, 64%
style
sortByColumn1
sortEnabledfalse
cellHighlightingtrue

NameTypeComments
maxDeviation
Specifies in mm how rigid the set of markers used to fill must be as the max deviation in distance between all pairs in the set. For example, a value of 60 would mean the markers may flex in rigidity by 6 cm.
maxDistance
Specifies how far away in mm the candidate can be from the selected marker. The default of 900 of900 is just under 3 feet, because anything more is likely another subject or body part which isn't likely to move rigidly during the gap.
percentTimeRigid
Specifies the percentage of time over the adjacent fragment ranges that the selected marker must be rigid with the chosen set. The default of 0.75 means 75% of the time.

...