  1. Ensure you have completed the rest of the camera calibration procedure and set the origin (see Set the volume origin ).
  2. Turn off the calibration object or remove it from the volume.
  3. Place a minimum of four 14 mm Vicon markers across the floor of your capture volume.
    (If you are not using 14 mm markers or have changed the default 7 mm floor plane setting, see Adjust the Set Floor Plane settings.)
  4. On the Camera Calibration tab, click Start Set Floor Plane.
    The button displays Set Floor Plane.
  5. After a few seconds, click Set Floor Plane.
  6. In the 3D Scene, display the View Filters options and under the Volume options, ensure that Cameras is selected
    In the Perspective view, note that the cameras shift as a group slightly along one or more rotation axes to better reflect an average of the markers scattered across the floor, taking into account any offsets that you specified.
    In C:\ProgramData\Vicon\Calibrations, the LatestCalibration.xcp file is updated. This file is automatically used for every subsequent capture.
    (tick) Tip: To more accurately visualize the size of your volume in Shogun Live, you can change the size and shape of the floor grid. To do this, on the Camera Calibration tab, click the ellipsis (...) next to Set Floor Extents and change the values (in mm) to give the required result.

...