This means that the timecode generator must also be capable of providing SDI reference video. This is usually an optional extra in timecode generators, and older models may not have it.
To set up the camera:
Ensure that the software on the camera is version 4.9 or later. This reduces video latency.
From the onscreen display, choose the correct video standard.
Set Reference Source to Program.
REF is now displayed on the camera monitor.
- Check that timecode is working correctly. The timecode should be in sync with the timecode generator and EXT should be displayed above TC on the camera monitor.