For instructions on setting up Vicon Vero systems, see the PDF Vicon Vero Quick Start Guide, which you can download from the Vicon website.
Scroll pagebreak |
---|
Vero camera status LEDs
Anchor | ||||
---|---|---|---|---|
|
Vero camera status LEDs
Location: Camera's Properties pane > Settings section
...
Info |
---|
Note In certain camera modes and in certain system configurations, the status LEDs on the camera are automatically turned off to ensure maximum power is available to the strobe. |
Scroll pagebreak |
---|
Anchor | ||||
---|---|---|---|---|
|
Vero Tap to Select camera feature
...
Location: Camera's Properties pane > Settings section
...
You can remove a camera’s Bumped status in Tracker. If this is a frequent occurrence, you can change its sensitivity to being tapped by reducing the Bump Detection Sensitivity. For more information, see the following section.
Scroll pagebreak |
---|
Anchor | ||||
---|---|---|---|---|
|
Vero bump detection and display
...
Location: Camera's Properties pane > Settings section and Camera's Properties pane > Status section
...
- Bump detection is active only on calibrated cameras.
- Bump detection cannot detect movement that does not change the local gravity vector, for example. slow translation with no rotation; rotation about the G-vector.
- Bump detection cannot detect movements that occur when the camera is not connected to a live system.
- The camera is detected as bumped when the reading from the accelerometer is sufficiently different from the last reading. Therefore gradual changes (for example, a slipping camera mount) may not be detected until they are large enough to trigger a new notification.
Scroll pagebreak |
---|
...
Anchor | ||||
---|---|---|---|---|
|
Vero temperature sensor display
Location: Camera's Properties pane > Hardware section > Camera Body Temp 1 andCamera Body Temp 2
...