After you have completed a wand wave (see Perform a wand wave), the next step is to set the volume origin.

Depending on your capture environment (for example, if your volume floor is not perfectly level), you may then need to set the floor plane. To further help with setting up your system, you may also want to set the floor extent and/or autonumber the cameras.

For further details, see:

Table of Contents
maxLevel2
minLevel2
 
Scroll pagebreak

...

Scroll only
scroll-viewporttrue
scroll-pdftrue
scroll-officetrue
scroll-chmtrue
scroll-htmltrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
22
Scroll pagebreak

Set the volume origin

Anchor
SetVolumeOrigin
SetVolumeOrigin

After you have captured a wand wave, you set the volume origin and axes so the cameras and volume in Tracker reflect the actual positions of the cameras in relation in your defined coordinate system, as well as to each other.

  1. To enable you to see the axes in relation to the volume, in the Workspace, change the view to 3D View.

    Image Modified

     

  2. Place the calibration device on the volume floor in the position you want the volume origin to be and in the orientation you want the axes to be (reflected in the axes displayed in the 3D View.

    Image Modified

    • X axis: red line
    • Y axis: green line
    • Z axis: blue line
  3. At the top of the Camera Calibration panel, to the right of Wand Wave, ensure Advanced Parameters is selected and in the wand list, ensure the appropriate Active Wand is selected (normally Active Wand v2).

    Tip

    (tick) Tip
    Using a Vicon Active Wand enables you to set up your volume coordinate system quickly and easily. However, using a larger calibration object (for example, markers embedded in the volume floor and wall) can improve calibration stability and consistency over time, particularly in larger volumes. For more information, see Create a custom calibration object.

  4. In the Volume Setup section, click Start Set Origin.
    The button displays displaysSet Origin and is unavailable until Tracker has enough data to set the origin.
    If you need more information about why the button is unavailable, hover the mouse pointer over the button to view its tooltip. For more information, see About collecting frames.
  5. Click Set Origin.
  6. In the 3D View, ensure that in the View Filters options, Cameras is selected.

    Image Modified

    Scroll pagebreak

    In the 3D View,  Perspective view, all of the cameras shift as a group, so the origin of the volume is aligned with the wand.  

About collecting frames

Anchor
AboutCollectingFrames
AboutCollectingFrames

...

If Tracker detects an issue with setting the origin, the tooltip for the Set Origin button displays the following information in the format 'Collecting frames (reason origin can't be set)' so that you can take the appropriate action:

Scroll tablelayout
style
orientationdefault
sortDirectionASC
repeatTableHeadersdefault
widths30%, 70%
style
sortByColumn1
tableStylingconfluence
sortEnabledfalse
cellHighlightingtrue

Tooltip text (reason)Action
L-Frame motion detectedEnsure the calibration object remains motionless while you are setting the origin.
No labeled dataNothing is being tracked in the volume. If you are using an active wand, ensure the wand is switched on. If the wand LEDs are blinking, switch to Continuous mode. 
L-Frame not trackedThe chosen calibration object was not detected. If you are using an active wand, ensure the wand is switched on. If the wand LEDs are blinking, switch to Continuous mode. 
Multiple objects detectedRemove any extra objects that are being tracked in the volume.
Insufficient framesThe calibration object hasn't been tracked in enough frames yet. Check that the L-frame is being tracked consistently.

...

The position of the virtual floor that is derived during origin setting process is extrapolated from the position of the wand in relation to floor of the volume. As the wand is a small object compared with the size of the volume, any slight discrepancy from the wand being level has a large effect over the rest of the volume when you set the origin. To account for any discrepancy, you set a floor plane, which takes a much larger area into account, so that the virtual floor lines up correctly with the actual floor plane.  

To set the floor plane:

  1. Ensure you have completed the rest of the camera calibration procedure and set the origin (see Set the volume origin).
  2. Turn off the wand or remove it from the volume.
  3. Scatter a quantity of the same size Vicon markers across the floor of your capture volume. If you want Tracker to automatically recognize these markers as floor plane markers, ensure that they outnumber any other groups of markers (e.g, markers on a wand or markers that were used to focus cameras, etc).
  4. Check to make sure the Height offset (mm) parameter is specified correctly. If you need to change this value setting, see Adjust the Set Floor Plane settings.
  5. In the Camera Calibration panel, ensure that to the right of Volume Setup, Advanced Parameters Image Modified is selected, expand the Set Floor Plane section and then click Start Set Floor Plane.
    The button displays Set Floor Plane.

  6. After a few seconds, click Set Floor Plane.
    In the 3D View, ensure that in the View Filters options, Cameras is selected.
    Scroll pagebreak

    In the Perspective view, notice that the cameras shift as a group slightly along one or more rotation axes to better reflect an average of the markers scattered across the floor, taking into account any offsets that you specified.

...

Adjust the Set Floor Plane settings

Anchor
AdjustFPSettings
AdjustFPSettings

When setting the floor plane, Tracker uses the center of all markers it has identified as being in the same plane. As the center of the marker is actually above the ground, you will need to specify an offset or else your floor plane (and Global Origin) may be higher than desired. To specify the proper offset, in the Camera Calibration panel, to the right of Volume Setup, ensure its Advanced Parameters are selected, expand the Set Floor Plane section and change the Height offset value to an appropriate value.

The Height offset is the amount (in mm) by which to adjust the floor plane (the default is 7 mm).

Image Removed
Panel
borderColor#00A474
bgColor#f3f9f4
borderWidth1
titleBGColor#f3f9f4
borderStylesolid
Tip

Tip
In general, to calculate the Height offset, add the radius of the markers to the thickness of the base of the marker. For a typical hard-based marker, this would give a Height offset of 9 mm (7 mm radius + 2 mm base thickness).  

Set the floor grid

To more accurately visualize the dimensions of your volume in Tracker, you can change the size and shape of the floor grid.

To do this:

  1. In the Camera Calibration panel, to the right of Volume Setup, ensure Advanced Parameters Image Modified is selected.

  2. Expand the Set Floor Grid section section and change the values (in mm) to produce the required result.
  3. Click Set Floor Grid.

Autonumber cameras

Anchor
AutonumberCameras
AutonumberCameras

...

The Auto Number Cameras feature numbers the currently connected Vicon cameras in ascending order, according to their position in the volume. You may want to do this after you calibrate your Vicon system, so that your cameras are logically numbered before you begin tracking.

...

  1. Ensure that the cameras are positioned as required, and that you have calibrated the cameras and set the volume origin.
  2. To enable you to check the camera numbering for all cameras, in the System panel, ensure that you can see the list of Vicon cameras.
  3. In the Camera Calibration panel, to the right of Volume Setup, ensure Advanced Parameters Image Modified is selected, expand the Auto Number Cameras section, and click Auto Number Cameras.
    The cameras are automatically numbered in ascending order, according to their position in the volume.

  4. In the volume, check that the cameras are now numbered as required by hovering your cursor over one of the cameras.