- To enable you to see the axes in relation to the volume, in the Workspace, change the view to 3D View.
- Place the calibration device on the volume floor in the position you want the volume origin to be and in the orientation you want the axes to be (reflected in the axes displayed in the 3D View.
- X axis: red line
- Y axis: green line
- Z axis: blue line
At the top of the Camera Calibration panel, to the right of Wand Wave, ensure Advanced Parameters
is selected and in the wand list, ensure the appropriate Active Wand is selected (normally Active Wand v2).Tip: Using a Vicon Active Wand enables you to set up your volume coordinate system quickly and easily. However, using a larger calibration object (for example, markers embedded in the volume floor and wall) can improve calibration stability and consistency over time, particularly in larger volumes. For more information, see Create a custom calibration object.
In the Volume Setup section, click Start Set Origin.
The button displays Set Origin and is unavailable until Tracker has enough data to set the origin.
If you need more information about why the button is unavailable, hover the mouse pointer over the button to view its tooltip. For more information, see About collecting frames.- Click Set Origin.
In the 3D View, ensure that in the View Filters options, Cameras is selected.
Scroll pagebreak In the 3D View, Perspective view, all of the cameras shift as a group, so the origin of the volume is aligned with the wand.
...