The RED Komodo camera is supported for SDI video in Shogun Live. Full details of how to set up and use the camera can be found in the Komodo Operation Guide. This document includes the extra information required to set up and use the camera with Vicon Shogun Live.

Image Removed

Scroll only
scroll-viewporttrue
scroll-pdftrue
scroll-officetrue
scroll-chmtrue
scroll-htmltrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
22

Scroll pagebreak

Image Added

Global shutter sensor

This camera has a global shutter sensor which makes it particularly suitable for use with the calibrated video feature of Vicon Shogun Live.

Scroll pagebreak

Sync and timecode

To calibrate the camera in Shogun Live, both genlock and timecode are required. The camera requires the RED Komodo Expander Module to give easy access to genlock and timecode. Ensure this is fitted according to the manufacturer's instructions.

Image Removed Image RemovedImage Added

Image Added

Two cables are required to connect the timecode generator to the Komodo Expander module: one for genlock and one for timecode. Scroll only

scroll-viewporttrue
scroll-pdftrue
scroll-officetrue
scroll-chmtrue
scroll-htmltrue
scroll-docbooktrue
scroll-eclipsehelptrue
scroll-epubtrue
3(Set up|Check).*

Scroll pagebreak

Set up the required timecode

  1. Connect the timecode to the BNC connector labeled Timecode.

    This must be the LTC timecode from the port on the timecode generator labeled TC, Timecodeor LTC.

  2. On the camera's onscreen display, select Menu > Audio / TC > Timecode Source and then select External.

    Image RemovedImage Added

Set up the required genlock

...

Any other colors (gray, red, yellow, etc) indicate a setup problem, which may not be immediately apparent in Shogun Live but which will cause problems for capturing calibrated video later. For more detailed information including the meaning of each status color, see the Komodo Operation Guide.

Status

On-screen display

Explanation

Genlock and timecode being received

Image Modified

(tick) Ready to capture in Shogun Live.

Genlock being received but not timecode

Image Modified

(error) Fix problems with camera setup before capturing or calibrating in Shogun Live.

Timecode being received but not genlock

Image Modified

Neither timecode or genlock being received

Image Modified

Note
Important
Shogun Live does not visually indicate whether the camera is getting a genlock signal and cannot tell whether the camera is getting external timecode or generating it internally, so you must check this on the camera itself.

Scroll pagebreak

Set up the SDI output

Connect the SDI output to the capture PC's capture card. If multiple outputs are required (eg, for a monitor), we recommend using an SDI distribution amplifier.

Image Added

Image Removed
Scroll pagebreak

Set resolution and frame rate

  • To set the resolution for the SDI output, on the camera's onscreen display select Menu > Monitoring > SDI > Resolution .
  • To set the frame rate, select Menu > Monitoring > SDI > Frequency.

    Image RemovedImage Added

Note
UHD and DCI
Shogun Live supports progressive video standards up to 4K, as long as a compatible capture card is used.
However, it has been more rigorously tested with the UHD standards (1920 × 1080, 3840 × 2160) than the DCI standards (2048 × 1080, 4096 × 2160).

...

On the camera's onscreen display, select Menu > Monitoring > SDI. Change all of Guides, Tools, and Overlay to 0 (red color, meaning off).

Image RemovedImage Added