Before you begin to connect your system components, check that your hardware is included in Recommended SDI video hardware. For setup instructions for the components, see:
To ensure that the camera shutters are aligned, the SDI camera must be genlocked to the Vicon system. This ensures that the SDI camera reliably see strobes from the Active Wand.
Timecode is used to identify the time at which data from the SDI camera and the Vicon system was captured. This ensures that the data from the two sources can be aligned. The calibrator can then determine any small remaining discrepancy and apply an offset to the video input to correct for it.
Consequently, both the SDI camera and the Vicon system must have a valid genlock signal and a valid timecode. Two cables are required to transmit reference sync and timecode to the camera, whereas the a single cable can carry both reference sync and timecode to the Vicon Lock unit.
Note In the following instructions and except where differences are noted, references to Vicon Lock units apply to Vicon Lock, Vicon Lock+ and Vicon Lock Studio. |
To connect the system components: