New features including the following have been added to Vicon Tracker 3.
: |
The following enhancements were added to Vicon Tracker 3.6.1:
Location: Resources pane > Objects tab > Object Type Preset section > Manage Presets > Objects Presets dialog box
You can now define an Entrance Threshold (the minimum proportion of markers that must be visible to the cameras before the object is booted) per object type in the Object Presets dialog box, instead of having to apply it globally for all objects.
To apply an Entrance Threshold to an object:
The VESA sync input on Vicon Lock devices now supports the connection of a 100 Hz square wave signal for synchronizing the Vicon system to an external clock.
The signal must be 5V peak, with a 50% duty cycle.
The following diagram shows the front view of a VESA sync input, which is a 3-pin mini-DIN socket.
The following new features were added to Vicon Tracker 3.6:
Several improvements to tracking include:
Location: Help > Check for firmware updates
Tracker provides a quick and easy way to check when new firmware is available for your cameras.
To check the latest release firmware version:
To check the firmware that your system is using:
Ensure the system is in Live mode, and in the System Resources pane, right-click Local Vicon System and then click Reprogram Vicon Firmware.
The firmware version currently used by your system is displayed in the Version column for every connected device.
To download the latest firmware, visit www.vicon.com/downloads/utilities-and-sdk/camera-firmware.
You can then update your firmware using the Reprogram Firmware dialog box.
Location: Resources pane > Objects tab > Object Type Preset section > Manage Presets > Objects Presets dialog box
You can now apply the Motion Model filter, which enables Tracker to detect static objects, to individual objects.
To enable Tracker to detect an object as stationary:
A version of Tracker 3.6 that runs under 32-bit Microsoft® Windows® is now available.
To obtain the 32-bit version, please contact Vicon Support.
Note Vicon recommends the use of the 64-bit version of Tracker, but the 32-bit version is provided to enable Tracker to be used on older PCs. However, the 32-bit version is provided as-is and with no guarantee of support. |
Location: System Resources pane > Vicon Cameras node > Vantage or Vero camera(s) selected > Properties pane > Settings section
A new Enable Strobe setting enables you to disable or enable strobes on Vantage or Vero cameras without affecting the shutter period.