Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Press F7 to open the Options dialog box.
  2. On the left click ForcePlates.
  3. In the Properties pane on the right, in the Force Vector section, change the Force Threshold (N) to the required value (the default is 25 N).
    Regardless of the setting of the Force Threshold in the System Resources pane, the forceĀ  vector that is displayed in the view pane is below the threshold that is set in the Options dialog box. For example, if you set the value to 10 in the System Resources pane, but left it at 25 in in the Options dialog box, a value of 15 would be prevented from causing flickering, but would be recorded in saved trials.

Anchor
ViewCombinedOutput
ViewCombinedOutput

View combined output from multiple force plates

You can combine selected outputs from multiple force plates, both in Live mode and when reviewing captured trials in Offline mode. For example, in trials where the subject's feet land on separate force plates, you can examine the combined landing force or overall CoP from both feet.

...