Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. In Shogun Live, in a 3D View, display the View Filters and ensure that Reconstruction Volume is selected, as well as any other options you want.
  2. At the top of the view pane, click the Reconstruction Volume Manipulator button.

    Image RemovedImage Added

    Scroll pagebreak

    The boundaries of the reconstruction volume (gray) and subject calibration hotspot (red) are displayed in the 3D View.

    Image Removed

    Image Added

To modify the reconstruction volume:

  1. If you want the reconstruction volume to match the current floor extents, on the Camera Calibration panel, in the Volume Setup section display the Advanced properties (click ).

  2. Ensure Set Floor Grid is expanded.
  3. Modify the size of the floor grid using the Min X and Y and Max X and Y fields.
    Scroll pagebreak
  4. Ensure Update Reconstruction Volume is selected.

    Image RemovedImage Added

    Scroll pagebreak
  5. Specify the size of the reconstruction volume (gray) in either of these ways:
    • Drag the gray arrows, which turn yellow on selection, to change the boundaries. (To move the position of the whole reconstruction volume, drag the gray diamond shape from the origin).
    • On the Processing panel, ensure the Advanced properties are displayed (click ) and in the Reconstruction section, change the values of Volume Min X, Y, and Z and of Volume Max X, Y and Z to reflect the required volume size and position.

      Scroll pagebreak

...

In a similar way as for the reconstruction volume, you can specify a subject calibration hotspot (red).

  1. Specify the size of the hotspot in either of these ways:

    • Drag the red arrows (which turn yellow on selection) to change the boundaries. (To move the position of the whole hotspot area, drag the red diamond shape from the origin).

      Click to view animationImage Modified

    • In the Tracking panel, on the Setup tab, ensure the Advanced properties are displayed (click ) and at the bottom, expand the Reconstruction section and change the values of Volume Min X, Y and Z, and Volume Max X, Y and Z to reflect the required subject calibration hotspot size and position.

      Scroll pagebreak

    The results of your changes are displayed in the 3D View.

  2. If required, move the subject calibration hotspot to a different part of the volume either by dragging the red diamond shape or by amending the Volume Min X, Y, and Z and of Volume Max X, Y and Z values in the Reconstruction section of the Tracking panel.

    Click to view animationImage RemovedClick to view animationImage Added