Capture Info section

PropertyDescription
Capture Folder

Enter or browse to the location of the folder in which to store captured data.

Note: by default, at least two files are saved for each capture: the raw camera data (.x2d) and the motion capture file (.mcp)

Default: C:\Users\Public\Documents\Vicon\Tracker4.x\Captures

Capture Name

Enter a suitable name that will enable you to identify the capture. This forms the first part (root) of the capture name. If Auto-increment Name is selected (see below), Tracker automatically adds a numerical suffix to the root capture name for each subsequent capture, for example, Capture001, Capture002, Capture003, etc.

Note: If the Capture Name matches any file name within the Capture Folder, Tracker will not allow you to select Start Capture.

Default: Capture

Auto-increment Name

If selected, appends a number at the end of the root capture name for each capture in a sequence consisting of multiple captures.

Default: Selected

Auto Capture section

You can configure Vicon Tracker to automatically capture data using these controls:

PropertyDescription
Start on Timecode

Select this check box and specify the timecode at which you want the capture to automatically start, using the format.

hh:mm:ss:ff

where: hh = hours (0-23), mm = minutes (0-59), ss = seconds (0-59), ff = frames (0-24 for PAL/SECAM, 0-29 for NTSC

For NTSC, the separator character changes between a colon ( : ) for non-drop frames and a semicolon ( ; ) for drop frames.

For further details on the use of timecode functionality in Vicon systems, see the Vicon Vantage Reference Guide or Vicon Systems Setup Guide.

Default: Cleared

Stop on Timecode

Select this check box and specify the timecode at which you want the capture to automatically stop, using the format.

hh:mm:ss:ff

where: hh = hours (0-23), mm = minutes (0-59), ss = seconds (0-59), ff = frames (0-24 for PAL/SECAM, 0-29 for NTSC)

For NTSC, the separator character changes between a colon ( : ) for non-drop frames and a semicolon ( ; ) for drop frames.

For further details on the use of timecode functionality in Vicon systems, see the Vicon Vantage Reference Guide or Vicon Systems Setup Guide.

Default: Cleared

Stop After Duration

To end the capture automatically after a specified number of seconds, select this check box and enter the required number of seconds.

Default: Cleared, 1.00 seconds

Broadcast Capture

Select this check box to enable broadcast capture functionality. This allows external systems on the local PC or network to be notified when Tracker has initiated a Capture.

Default: Cleared

Triggered CaptureSelect this check box to enable triggered capture functionality. This allows another app on the local PC or network to trigger a capture within Tracker.
Port

Specify the computer port number to be used for triggered capture.

Default: 30

Address Select the IP address to be used for triggered capture. The selections available within this dropdown are dependent on your specific PC configuration but you can choose to specify All available IPs or choose a specific IP address

Default: All

Capture section

Specify the type of motion data to be captured by your Tracker system.

PropertyDescription
Capture Analog

Select to capture analog signals from any connected analog devices.

Default: Selected

Capture Processed Data

Select to capture marker images visible to the Vicon optical cameras. It is not recommended to clear this parameter if you want to review your captured data.

Default: Selected

Capture Buffer Size

Specify the required buffer size for capturing, in MB.

Default: 2048