Vicon Vantage troubleshooting

Vicon Vantage troubleshooting

If something is not quite right, try these quick tips to get things going again.

Vantage system components

I am missing some equipment
or
Some equipment appears damaged from shipment.


Connecting

My hardware isn’t connecting to the computer.

  • Confirm that the IP address settings are correct following the instructions in Connect and configure the PC.
  • Check the network card settings, including Jumbo Packet (for details, see Configuring network card settings or Configuring and connecting the network ports in the PDF PC setup for Vicon systems).
  • Disable any firewall on the network card.
  • Confirm that the Ethernet cable is firmly seated.
  • Ensure you are an administrator on the computer.

Camera hardware

I don’t see an image from the camera.

  • Confirm that you've removed the lens cap.
  • Ensure that the aperture is not fully closed.
  • Confirm that the Strobe Intensity is high (best on full at 1) and that the Threshold is not too high (a good default is 0.2).

When I tap a calibrated camera to select it, the camera indicates that it has been bumped.

  • To change the sensitivity of the camera to taps, in the camera’s Properties pane, Settings section (Nexus and Tracker) or General section (Shogun Live), choose a lower Bump Sensitivity setting.

Calibrating cameras

After calibrating, image errors are very high.

  • Ensure that the camera aim and focus are correct, the camera properties are set appropriately, and that you covered the whole volume during your wand wave, then repeat the calibration.
  • Ensure Active Wand is selected in the Calibrate Cameras settings (Nexus and Tracker) or Camera Calibration tab (Shogun Live).

If you need more information than that supplied in the documentation or
on the Vicon Support web pages, please contact Vicon:

Denver, CO
Vicon Denver
12650 E Arapahoe Rd
Suite 200, Centennial
CO 80112, USA
T: 303.799.8686
F: 303.799.8690
E: support@vicon.com
Los Angeles, CA
Vicon LA
3750 S. Robertson Boulevard
Suite 100, Culver City, Los Angeles
CA 90232, USA
T: 310.437.4499
E: support@vicon.com
Oxford, UK
Vicon Oxford
6 Oxford Pioneer Park
Yarnton, Oxfordshire
OX5 1QU, United Kingdom
T: +44.1865.261800
E: support@vicon.com

Related content


© Copyright Vicon Motion Systems. All rights reserved.

Vicon trademarks