Valkyrie system diagrams
Up to 8 Valkyrie cameras
With a single switch to connect up to eight Valkyrie cameras.
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per simple switch)
- Cat 6 (minimum) Ethernet cable
- Simple switch – Netgear GS516UP
- PC
Up to 8 Valkyrie cameras with Vicon Lock
With a Vicon Lock added to the system for up to 8 Valkyrie cameras.
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per simple switch)
- Cat 6 (minimum) Ethernet cable
- Simple switch – Netgear GS516UP
- Vicon Lock
- PC
Up to 80 Valkyrie cameras
With up to 8 Valkyrie cameras per power switch and up to 10 power switches per data switch, using the 10 GB uplink and direct attach (SFP+) cable to connect power switches to the data switch.
The data switch connects to the PC via Ethernet, with an SFP+ transceiver.
The Lock power switch is used whenever a Lock needs its own power source and is connected to the data switch via an Ethernet cable with an SFP-10G-T-PLU SFP+ transceiver.
Note
Use only SFP-10G-T-PLU SFP+ transceivers with the Lock power switch.
If your system requires a longer length (50 m) cable to connect the power switch to the data switch, a 50 m Ethernet cable with two SFP+ transceivers is required.
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per power switch)
- Cat 6 (minimum) Ethernet cable
- Power switches: Netgear GSM4212UX, aka M4250-10G2XF-PoE++ (up to 10 per data switch)
- 10 Gb SFP+ Direct Attach Cable (eg, Netgear AXC763) per power switch
- Data switch - SFP+ (primary switch): Netgear M4250-16XF (XSM4216F)
- Vicon Lock
- Lock power switch (eg, Netgear GS108LP)
- 10GBase-T SFP+ transceiver (eg, Netgear AXM765) to connect data switch to PC. For details, see SFP+ transceivers for Valkyrie systems.
- SFP-10G-T-PLU SFP+ transceiver to connect Lock power switch to data switch. For details, see SFP+ transceivers for Valkyrie systems.
- PC
EN 60601-compliant Valkyrie system
This diagram is an example of a system that meets EN 60601 standards for medical compliance and therefore includes an isolation transformer between the mains power supply and the Ethernet switches. As in the previous example, this diagram shows a system with up to 8 Valkyrie cameras per power switch and up to 10 power switches per data switch, using the 10 GB uplink and direct attach (SFP+) cable to connect power switches to the data switch.
Important
If your system must meet EN 60601 standards for medical compliance, ensure that you have received from Vicon the appropriate number of isolation transformers for your system (one for each 24 cameras connected via up to 4 Ethernet switches). As shown in the diagram, you must connect the isolation transformer between the mains power supply and the Ethernet switch(es).
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per power switch)
- Cat 6 (minimum) Ethernet cable
- Power switches: Netgear GSM4212UX, aka M4250-10G2XF-PoE++ (up to 10 per data switch)
- 10 Gb SFP+ Direct Attach Cable (eg, Netgear AXC763) per power switch
- Data switch - SFP+ (primary switch): Netgear M4250-16XF (XSM4216F)
- Vicon Lock
- Lock power switch (eg, Netgear GS108LP)
- 10GBase-T SFP+ transceiver (eg, Netgear AXM765) to connect data switch to PC. For details, see SFP+ transceivers for Valkyrie systems.
- SFP-10G-T-PLU SFP+ transceiver to connect Lock power switch to data switch. For details, see SFP+ transceivers for Valkyrie systems.
- Isolation transformer REOMED I 1000, one for each 24 cameras connected via up to 4 Ethernet switches, with the transformer connected between the mains power supply and the Ethernet switch(es)
- PC
Note
Use only SFP-10G-T-PLU SFP+ transceivers with the Lock power switch.
Up to 160 Valkyrie cameras
With up to 8 Valkyrie cameras per power switch and up to 10 power switches per data switch, using the 10 GB uplink and direct attach (SFP+) cable to connect power switches to the data switch.
Note
Use only SFP-10G-T-PLU SFP+ transceivers with the Lock power switch.
To double the number of Valkyrie cameras that can be connected (up to 160 Valkyrie cameras), two Ethernet cables, each with its own SFP+ transceiver, are required to connect the primary data switch to the PC.
If your system requires a longer length (50 m) cable to connect the power switch to the data switch or to connect data switches, a 50 m Ethernet cable with two SFP+ transceivers is required.
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per power switch)
- Cat 6 (minimum) Ethernet cable
- Power switches: Netgear GSM4212UX, aka M4250-10G2XF-PoE++ (up to 10 per data switch)
- Data switches (SFP+): Netgear M4250-16XF (XSM4216F)
- 10 Gb SFP+ Direct Attach Cable (eg, Netgear AXC763) per power switch and to connect data switches
- Vicon Lock
- Lock switch (eg, Netgear GS108LP)
- 10GBase-T SFP+ transceivers (eg, Netgear AXM765) to connect data switch to PC. For details, see SFP+ transceivers for Valkyrie systems.
- SFP-10G-T-PLU SFP+ transceiver to connect Lock power switch to data switch. For details, see SFP+ transceivers for Valkyrie systems.
- PC
Link aggregation for multiple NICs
- Set the additional IP addresses of your NICs to different addresses in the available range 192.168.10.2–9.
- In your Vicon application software, in the Properties pane for each camera, set the Destination IP Address to the IP address of the NIC to which to send data.
Mixed system with Vantage or Vero cameras (up to 16 Valkyrie cameras)
To add up to 16 Valkyrie cameras to an older system of up to 12 Vantage cameras or 23 Vero cameras and a Lock, the Valkyrie cameras are added to the existing system by connecting them to the primary switch.
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per power switch, to a total of 16)
- Cat 6 (minimum) Ethernet cable
- Primary switch: DLink DGS-1520-28MP
- 10 Gb SFP+ Direct Attach Cable (eg, Netgear AXC763) per power switch
- Power switches (PoE++): Netgear GSM4212UX, aka M4250-10G2XF-PoE++
In this example, the older Vicon system consists of:
- Up to 12 Vantage cameras or 23 Vero cameras
- Gigabit PoE+ switch: DLink DGS-1520-28MP
- Vicon Lock
- PC
Mixed system with Vantage or Vero cameras (more than 16 Valkyrie cameras)
To add more than 16 Valkyrie cameras to an older system, the older cameras (and Lock) are added to a new Valkyrie system via the data switch.
If your system requires a longer length (50 m) cable to connect the power switch to the data switch or to connect data switches, a 50 m Ethernet cable with two SFP+ transceivers is required.
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per power switch)
- Cat 6 (minimum) Ethernet cable
- Data switch (SFP+): Netgear M4250-16XF (XSM4216F)
- 10 Gb SFP+ Direct Attach Cable (eg, Netgear AXC763) per power switch and to connect the old primary switch to the data switch
- Power switches (PoE++): Netgear GSM4212UX, aka M4250-10G2XF-PoE++ (up to 10 per data switch)
- 10GBase-T SFP+ transceivers (eg, Netgear AXM765) to connect data switch to PC. For details, see SFP+ transceivers for Valkyrie systems.
- SFP-10G-T-PLU SFP+ transceiver to connect Lock power switch to data switch. For details, see SFP+ transceivers for Valkyrie systems.
In this example, the components from the older Vicon system consist of:
- Up to 12 Vantage cameras or 24 Vero cameras
- Gigabit PoE+ switch: DLink DGS-1520-28MP
- Vicon Lock
- Lock power switch (eg, Netgear GS108LP)
- PC
Valkyrie system with FLIR Blackfly S camera
A FLIR Blackfly S camera and a Vicon Lock Lab are added to the system for up to 8 Valkyrie cameras.
Note
To include FLIR cameras in your Vicon system, ensure your hardware meets or exceeds the specifications in Recommended FLIR Blackfly S hardware for Nexus in the FLIR Cameras Setup Guide, and includes a suitable USB 3.1 host controller card and high-speed (M.2) SSD.
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per power switch)
- Cat 6 (minimum) Ethernet cable
- Power switches (PoE++): Netgear GSM4212UX, aka M4250-10G2XF-PoE++ (up to 10 per data switch)
- Teledyne FLIR Blackfly S camera
- USB 3 Cable
- PC
Valkyrie system with FLIR Blackfly S camera with two Locks
With up to 8 Valkyrie cameras per power switch and up to 10 power switches per data switch, using the 10 GB uplink and direct attach (SFP+) cable to connect power switches to the data switch.
The data switch connects to the PC via Ethernet, with an SFP+ transceiver.
The Lock power switch is used whenever a Lock needs its own power source and is connected to the data switch via an Ethernet cable with an SFP-10G-T-PLU SFP+ transceiver.
If you use an optional, additional Lock, connect each Lock to the Lock power switch with one Ethernet cable per Lock.
Note
Use only SFP-10G-T-PLU SFP+ transceivers with the Lock power switch.
Components
Currently available and suitable for use in this configuration:
- Valkyrie cameras (up to 8 per power switch)
- Cat 6 (minimum) Ethernet cable
- Power switches: Netgear GSM4212UX, aka M4250-10G2XF-PoE++ (up to 10 per data switch)
- 10 Gb SFP+ Direct Attach Cable (eg, Netgear AXC763) per power switch
- Data switch - SFP+ (primary switch): Netgear M4250-16XF (XSM4216F)
- Vicon Lock (up to two)
- Lock power switch (eg, Netgear GS108LP)
- 10GBase-T SFP+ transceiver (eg, Netgear AXM765) to connect data switch to PC. For details, see Valkyrie system diagrams.
- SFP-10G-T-PLU SFP+ transceiver to connect Lock power switch to data switch. For details, see Valkyrie system diagrams.
- PC
If your system requires a longer length (50 m) cable to connect the power switch to the data switch, a 50 m Ethernet cable with two SFP+ transceivers is required.