Preferences parameters

Preferences parameters

On the User tab in the Preferences dialog box (Settings menu > Preferences), you can view and/or change the following settings.

Folders section

Option Description
Calibration Objects Specifies where Evoke and other Vicon software saves all custom calibration objects. This does not include the standard calibration wand objects, which can be found in:
C:\Program Files\Vicon\Evoke1.#\CalibrationObjects

Files in this folder are VSKs.
Default location:
C:\Users\Public\Documents\Vicon\CalibrationObjects
Objects

Specifies where Evoke saves all exported objects from the Tracking panel. Files in this folder are VSKs.
Default location:
C:\Users\Public\Documents\Vicon\Objects

Prop Meshes

Specifies the folder Evoke opens when loading a prop mesh. Files in this folder are FBXs.
Default location:
C:\Users\Public\Documents\Vicon\PropMeshes

Scene Meshes Specifies where scene meshes (FBX files) are located.
Default location:
C:\Users\Public\Documents\Vicon\SceneMeshes
Retargets Specified where retargets (VSR files) are located.
Default location:
C:\Users\Public\Documents\Vicon\Retargets
Skins Specifies where skins (FBX files) are located.
Default location:
C:\Users\Public\Documents\Vicon\Skins
Smart Object Templates

Specifies where Smart Object templates are located.
Default location is:
C:\Users\Public\Documents\Vicon\SmartObjectTemplates.

General section

Option Description
Alt key to select in views When selected, holding down the ALT key enables you to:
  • Draw a box with the left mouse button in 2D and 3D views to multi-select centroids, markers, or objects
  • Draw a box with the right mouse button in Graph Plots to zoom in on a range of data
Default: Selected
Middle mouse button scrub in 2D & 3D views When selected, holding the middle mouse button and dragging left or right enables you to scrub backward and forward through review data.
Default: Selected
Middle mouse button scrub sensitivity Controls the sensitivity of the cursor when used for scrubbing with the middle mouse button.
Default: 5
Mouse wheel jog in 2D & 3D views Controls the increment of frames progressed (forward or backward) when using the mouse wheel to scrub through review data.
Default: 5
Enable auto-save When selected, enables the system to automatically save certain configuration files. For details, see Vicon Evoke fundamentals.
Default: Selected
Ask before recovery of latest settings When selected, if Evoke is started from an unexpected shutdown, you are prompted to choose which settings to use. For details, see Vicon Evoke fundamentals.
Default: Selected
Auto-save interval Controls the interval (in seconds) in which Evoke auto-saves its configuration files. Changing this setting has no effect if Enable auto-save is cleared.
Default: 60 seconds
Start playing automatically in review mode When selected, captures loaded in Review mode begin immediately upon loading.
Default: Cleared
Warn if free space on optical data capture drive is low When selected, Evoke warns you when your current drive is below its Optical free space warning threshold (see below).
Default: Selected
Optical free space warning threshold Controls when (in GB) the free space warning is issued. If the Warn option (see above) is cleared, changing this setting has no effect.
Default: 50 GB

Update Notificationssection

Option Description
Show notification for application version 1.4.1.138304h When selected, Evoke notifies you if an updated version of Evoke is available. For this feature to work, you must be connected to the internet.
Default: Selected
Show notification for firmware version 725 When selected, Evoke notifies you if your firmware is out-of-date.
Default: Selected

Subject Storesection

Option Description
Automatically manage smart object patterns When selected, a unique pattern is automatically assigned to each Smart Object, where possible. If you are tracking multiple identical objects, clear this option (for details, see Track multiple identical objects).
Default: Selected
Enable object evaluation When selected, the system performs object evaluations in the background. For more information. see Understand object evaluation.
Default: Selected
Object evaluation step limit

Maximum number of steps to allow for evaluating each object pair. Increasing this value provides more certainty that object similarities do not exist but results in decreased performance.
Changing this option has no effect if Enable object evaluation is cleared.
Default: 1000

Object confusion warning threshold (mm)

Threshold for differences between objects (in mm). This warning indicates the object either closely matches another object or another view of itself (see Understand object evaluation).
Changing this option has no effect if Enable object evaluation is cleared.
Default: 6.00 mm

Channel Cache section

Option Description
Cache Memory Limit (MB)

Sets the limit for the amount of channel data saved to memory before it is written to disk.
Note: The path for channel data written to disk is configurable at Preferences > System > User Data Folder
Default: 512 MB

Graph Plots section

Option Description
Trace colors

Controls the number of unique colors to be used for traces. You can choose between 9, 12, and 22 colors. The lower number of colors may assist those with limited color vision.
Default: 22 colors

Enable rotation unwrapping

When selected, angles are unwrapped when they exceed the typical (-π, π) radians range (see Graph Plots reference).
Default: Selected

Show pan/scale overlay graphics

When selected, graphics (such as the dead zone) for zoom/pan/scale will appear in the window (see Change the scale of graphed data).
Default: Selected


© Copyright Vicon Motion Systems. All rights reserved.

Vicon trademarks