Configure system settings
You configure settings relating to your Vicon Tracker system hardware in the System panel. It contains the following components:
Component | Description | |
---|---|---|
System panel properties |
Display or change the requested frame rate. To display other system settings, select Advanced Parameters (at the top right of the System panel). |
|
System panel sections |
Select the system component that you want to configure from the relevant section:
|
|
System component properties |
View or modify properties of the selected system component(s) in the pane in the lower part of the System panel. The properties displayed depend upon the component(s) selected in the System panel sections. |
To import, save, and manage System panel settings:
-
Click the System Settings menu
on the right of the Tracker menu bar to open the Manage System Settings dialog box.
To perform commands specific to a type of system component node:
- In the System panel, right-click the required component and select a command from the context menu.
System properties
At the top of the System panel, you can access the following system-wide settings. They affect all the connected cameras and devices:
Control | Description |
---|---|
Frame Rate | The requested rate (in Hz) at which to synchronize the Vicon cameras. Default: 120 Hz. |
Genlock Setup | Choose to lock to an external genlock signal and to select a genlock standard. The type of video standard supported by the connected video source: None, PAL, NTSC, Film, 30Hz, VESA, SDI and SteamVR™ (to display the complete list, click in the Genlock Setup field). In the list, the icon to the left of each option provides additional information about the availability of that standard. Note: The 30Hz option enables you to run the Vicon system at multiples of 30 frames per second (above 50 fps), with timecode and genlock capability at true 30 fps, and works with Vicon Locks. Default: No genlock (ie, locking to an external genlock signal is not selected), None. |
Timecode Setup | Choose to lock to an external timecode signal and to select a timecode source. Default: No timecode lock, None. |
Genlock Offset | Specify a system offset relative to the genlock signal, as a fraction of the genlock frame period. For VESA modes, use the VESA Offset control. Default: 0.00 |
VESA Offset | Specify a system offset relative to the VESA signal, as a fraction of the VESA frame period. For non-VESA modes, use the Genlock Offset control. Default: 0.00 |
Preferred Sync Source
|
Enables you to choose the device (known as the sync source) that provides the overall synchronization signal to the system. You can select from these options:
In the System panel, the entry for the device selected as the Vicon system sync source, is displayed in bold.
|
Enable Tap-To-Select | Enable the Tap-to-Select feature of cameras that are equipped with accelerometers. Default: Selected |
Enable Strobes | Enable the strobes on cameras. Default: Selected |
Force Lowest Latency | When selected, forces Vicon cameras that offer this option into a mode that provides the lowest possible latency at the cost of reducing grayscale and centroid throughput. Generally, this mode is only useful when you're using low latency object tracking. Caution: In some systems with high numbers of cameras, selecting this option may cause network issues that are manifest as cameras appearing to drop out. Default: Selected |
For information on the system components listed in the System panel, see Configure Vicon cameras, Configure Vicon connectivity devices, and Configure analog devices.
The node for the device currently designated as the Vicon system synchronization source is displayed in bold in the System panel. See Preferred Sync Source.